Concentric vent installation

A Concentric Diffuser provides conditioned air from a HVAC rooftop unit to a space, while returning air back to the rooftop unit through the same diffuser. Note 2: System 636 PVC concentric terminations utilize PVC pipe/fittings certified to ULC S636. Determine correct concentric vent termination accessory for the pipe diameter selected. • Read owner’s manual before using/installing. The installation instructions should be kept with the appliance for  This Horizontal Concentric Vent Kit utilizes one 8 inch termination in which both the discharge flue gas and the combustion air inlet pases. both the vent/flue pipe and the combustion air intake pipe. national 3 Inch Concentric Vent Termination Allows both the intake for combustion air and the exhaust vent to pass through a common roof or sidewall penetration Kit contains 1 each: combustion air inlet cap; air inlet pipe; vent pipe; intake/vent concentric "Y"; installation instructions Concentric vent terminational kit for water heater. Featuring Snap-Lock joints that are quick and easy to disconnect, the AmeriVent Type B gas installation must conform with the specifi cations listed in the tankless water heater installation manual. Email. These vents save time and money by reducing the amount of work required. Concentric Vent Box Assembly (See Figure 1) (1) Part No. 28-30 5. 21 Using an Existing Vent System to Install a New Boiler . Created Date: 6/4/2009 1:11:36 PM CONCENTRIC VENT SIDE WALL 5 CONCENTRIC VENT SIDE WALL INSTALLATION 6 NOTE: Instead of cementing the smaller pipe to the rain cap, RTV silicon sealant may be used to permit future field disassembly for cleaning. UPC: 95247156658. 13. O nce venting is complete, proceed to the section titled "Installation - Gas Connections" in the unit Installation & Service Manual. 8. This is "Concentric Vent Kit & Wind Effects" by Sigler Wholesale Distributors on Vimeo, the home for high quality videos and the people who  Exhaust Vent Combustion Air Inlet Ubbink Concentric-to-Twin Pipe All PVC/CPVC IPEX Concentric Vent Kit assemblies are certified to ULC  Items 1 - 10 of 21 Compatible with all WaiWela, Rheem, Rhuud, EcoSense and Richmond models. 2 concentric vent kits: either maintain a 24" minimum distance apart, or have the rain caps no more than 4" apart 3 concentric vent kits: Option 1 - keep all 3 kits at least 24" apart. A. An unvented dryer puts all kinds of fibers and lint into the air in the house that will not only accumulate and make a heck of a mess over time, but can cause resp Having your dryer properly vented is crucial in keeping the appliance operating effectively and avoiding the risk of fire or water damage to your home. The 24 volt, draft induced units include a standard vent kit that can be cut to fit wall thicknesses from 5″- 32″ and includes an external vent cap Concentric vent terminational kit for water heater. Using an Existing Vent System to Install a New Water Sidewall Termination - Optional Concentric Vent . The installation, starting up, and Installation: Concentric Vent Terminal . • Do not install DirectVent Pro installation of the intake/vent pipe(s) and all furnace installa-tion procedures. . (For models manufactured prior to 2008 a separate condensate collector is available) Plastic vent components consist of an outer plastic vent for the air intake followed during the installation, servicing, and opera-tion of this furnace. Model/Part #: LB-49107CG. Determine the best location for the Concentric Vent. In cases in which the Installation Instructions do not address the vent length for the specific number of elbows required for a particular application, the following calculations may be used. ), lightweight (60 lbs. 12"(300mm)min. For each penetration, cut a 7” diameter hole through the structure. This is an alternative to the standard two pipe intake/vent shown in the basic furnace installation instructions. PolyPro Concentric vent system parts, including the concentric Horizontal Termination and the Vertical Termination, are listed at 0” clearance Carrier® Vent Terminal Kit, Concentric, Series: KGAVT, For Use With: Model 59SC2B Condensing Gas Furnace, 10 in W x 39 in D x 7-1/2 in H, Domestic Carrier_KGAVT0701CVT_installation_instruction () Type PVC Concentric Vent Manual Recess Box Water Heater Configurations & Installation Greentherm Replacing Control Unit: Models C150ES, C950ES Type Installation Manual Configurable sizes to meet installation requirements. Use only with the type of gas approved for this furnace. The AmeriVent gas vent line allows you to create almost any system from our more than 350 coordinated parts. Thespecial vent fittings and accessory concentric vent termination kits and accessory external drain trap have been certified to ULC S636 for use with those IPEX PVC vent components which have been certified to this standard. It allows for an easy installation of high efficiency tankless water heaters. Horizontal Vent Kit Installation Instructions. 00! Option CC14, the Compact, Aesthetic, Concentric Vent/Com-bustion Air, Horizontal Vent Kit is for use with Model UDAS and UDBS in sizes 30, 45, 60, and 75. Vent systems listed to UL 1738can be plastic or mantellic, flexible or rigid, and can be single wall or concentric vent systems. Both combustion-air and vent pipes must attach to the termination kit. TM) (UL 1738 / ULC S636) INSTALLATION INSTRUCTIONS ® Do NOT mix pipe, fittings, cements, or joining methods from different manufacturers, this can result in unsafe . Partially assemble concentric vent termination kit. Installation Supplies > Kits / Adapters. O. Instead of a separate hole for the exhaust pipe and a separate hole for the combustion air intake pipe, this kit merges the two pipes into a single concentric vent pipe which passes through the wall or roof. 2 Maximum Vent Length 8. InnoFlue® Flex is used to vent individual appliances. Quick Installation Guide Model NPE-180A / 210A / 240A NPE-150S / 180S / 210S / 240S 1 Lift up the water heater, rest the unit Concentric Vent Termination (1. Read this supplement and the unit heater installation, concentric vent kit, or 5” in diameter for 3” concentric vent kit. Inc. And energy costs seem sky high and climbing. We have several resources to help; The Chimney Cap Buying Guide and the Chimney Pipe Buying Guide will help you find out what your options are and how AmeriVent is a complete gas venting system, from 3” to 30” pipe diameters in 7 different pipe lengths, to single- to multi-appliance hook-ups. The newly certified vent system is comprised of a Concentric to Twin Pipe Adaptor (adaptable to 3 and 4 inch sizes), PVC/CPVC pipes, fittings and either the IPEX Concentric Vent Kit (CVK) Assembly (System 636), snorkel PLASTIC VENT COMPONENTS For concentric venting, non-condensing models. Twitter. They’re extremely well engineered, quiet, compact (2. If these instructions differ from those. Updating Price Sign in to view pricing. hotwater. Installing and servicing water heating  The Ubbink Rolux® concentric vent system was tested and approved with the appliance by a third party testing agency. The concentric vent adaptor allows for the combustion air  Installations Instructions. Refer to Figures 1 - 4 for installation clearances in different installation scenarios. 13, the manufacturer’s specifications, and the following: 1. unit shall be complete with a permanent non-adhesive anti-sweat gasket and Concentric Vent Kit Installation Guide 8-1/8” 7-1/2” 20-34” 25-3/16” 4-1/2” 4-15/16” 5-15/16” 12-3/4” NotICe It should be noted that a mild flow reduction may be realized with the use of a concentric vent. 3 5H75153 Rev C December, 2012 INSTALLATION AND SERVICE MANUAL Concentric Venting and Two Pipe  This Installer's Guide covers installation of the concentric vent kit on all gas fired direct vent condensing furnaces. HJ, the other side is the gas meter and the other wall will have a porch there in the future SO,,,, looks like I am going on the roof and return this concentric vent. Diversitech CVENT-3 Concentric Vent, 3 in Vent. Option 2 - group 2 kits close together up to a maximum of 4” apart and the third kit over 24” apart. VENTING in the installation and operation manual supplied with the heater except as follows: 1. 1CT0303 is for use with 3" intake/vent systems. 5" Concentric Vent Kit. Smith Water Heaters, 500 Tennessee Waltz Parkway, Ashland City, TN 37015 PHONE: 1-800-433-2545 • FAX: 1-800-433-2515 www. This DiversiTech CVENT-3 Concentric Vent simplifies installation and only requires one hole through the wall or roof where the pipes terminate. 4. Current water heater models incorporate a condensate collector and do not require an “adapter” vent component. (The total vent system length includes all straight and curved portions of the vent system. The Pinnacle Oil boiler, like all high efficiency products, is likely to produce a visible vapor plume Easy Installation and Service • 1/2" Gas line compatibility up to 24 ft. This option allows a hom-eowner to vent out a side wall and avoid the unsightly 18" to 36 Keep mice, birds, and toys out of your furnace vent AS they could result in a costly repair. Add to Cart. 2 cu. 3" Concentric Vent Screen Kit with 2-1/2" Diamond Vent Screen. It is very important to properly glue all joints. I didn't conduct the "final"  This instruction manual covers installation of the 2” and 3” concentric vent termination kit for use on HTP boilers and water heaters. This option allows a hom-eowner to vent out a side wall and avoid the unsightly 18" to 36 Installation in Canada must conform to the requirements of CSA B149 code. Figure 1 • Kit Contents This instruction sheet is intended to describe the installation of the Concentric Vent Kit. Use 4. Inside Corner Caulk Caulk Caulk If soft vent is too close, block off and install new vent at another location. This is an alternative to the Installation Instructions Concentric Vent Termination Kit for Condensing Furnaces INTRODUCTION These instructions are intended to assist qualifi ed individuals in the proper installation of this concentric vent termination kit. INSTALLATION PRECAUTIONS • Do not install DirectVent Pro Concentric Flex through walls, ceilings, floors, or any fire-rated assemblies unless specifically approved by the appliance manufacturer. 95. of installation. Optional safety features include hinged doors, hydrogen monitors and vent fans. Do not common vent or connect any vent from other appliances to the water heater vent. Up to 100 CFM - 3% Up to 160 CFM – 7% Up to 200 CFM – 11 % Concentric CONCENTRIC VENT TERMINATION KIT 3 6. 2. 6) Follow local gas codes in your region or refer to National Fuel Gas Code. DiversiTech's CVENT series concentric vent kit includes all fittings a contractor will need to install the vent. Two concentric intake/vent termination accessories are avail-able. Cut a 4” diameter hole for CVENT-2, 2” kit. You HAD to use the fitting to start the vent. Concentric Horizontal Vent Kit. Field convertible from natural gas to propane. 8 m) 4' (1. Features. Installation Instructions Concentric Vent Termination Kit for Condensing Furnaces INTRODUCTION These instructions are intended to assist qualifi ed individuals in the proper installation of this concentric vent termination kit. NOTE: Do not allow insulation or other materials to Installation of Compact, Aesthetic Concentric Vent/Combustion Air, Horizontal Vent Kit, Option CC14 Form I-UDAS/UDBS-ASC (209344 R7) Obsoletes Form I-UDAS/UDBS-ASC (Version A. Installation and service must be performed by a qualified installer, DIRECT VENT TANKLESS WATER HEATERS Acceptable Venting Clearances For IPEX Concentric Vent installation and nstructions of the vent maintenance i system. Vent components consist of an outer plastic vent for air intake (5" diameter) and an inner polypropylene vent for the exhaust gases (3" diameter). A gable vent is an important part of the heating and cooling of your home. Straps are field supplied. 0 GPM. Fortunately, installing a dryer vent is easy to do. The vent kit is ideal if you do not want to cut two holes in your roof or wall to vent the furnace. Multiple Vertical Concentric Vents Concentric Vent Installation Instructions 22152-22153 Concentric Vent Termination For use with all condensing gas furnace models General The Concentric Vent allows both the intake for combustion air and the exhaust vent to pass through a standard roof or sidewall. 3 Vertical or Horizontal Vent Termination 8. 200 Houston, TX 77071 Toll: 1. Designed to deliver air into an open space, or just below the ceiling of an occupied space using a very short distance. 6 720 812 236 (2014. Keep mice, birds, and toys out of your furnace vent AS they could result in a costly repair. Concentric PVC is a thing. ft. 1. 3 Inch Concentric Vent Termination Allows both the intake for combustion air and the exhaust vent to pass through a common roof or sidewall penetration Kit contains 1 each: combustion air inlet cap; air inlet pipe; vent pipe; intake/vent concentric "Y"; installation instructions LB-49107CG 1. It can be used for vent systems with a maximum of 15 linear feet (4. Inform, Inc. CNKT-0560-18HD Installation Instructions from MicroMetl Corporation on May 2014. They have combustion air supplied from the exterior (some water heater PVC vent pipe systems might be 2 pipes starting at the water heater and converted into one concentric Concentric vent terminational kit for water heater. Hub size: Large end = 7 1/4”, Small end = 3-1/4", Outer Flange Diameter = 9-1/2". Flexible installation - the same CVENT series vent kit can be used in either a horizontal (through the wall) or vertical (through the roof) installation; DiversiTech's CVENT series concentric vent kit includes all fittings a contractor will need to install the vent; No additional fittings for outside connections are needed Reduce installation and maintenance costs for your Modine Hot Dawg HDS Heater with this Horizontal Concentric Vent Kit for HDS60-HDS125 heaters. Vent termination shall not be located at lot line walls or within three feet of lot lines; 10215 South Sam Houston Parkway West, Ste. Three Concentric Vent products are available: CVENT-2 is for use clearances. intake/vent systems. This concentric vent termination kit may be used with 3 inch diameter. 11 Sidewall Termination - Optional Concentric Vent . 4 Combining Category IV Vent 8. installation of the intake/vent pipe(s) and all furnace installa-tion procedures. Learn how to install attic vents at HowStuffWorks. This kit allows Revolv MG2R and MG2S high efficiency furnaces to use a single vent  Tankless Water Heater 3”/ 5” Concentric Direct Vent. There are also single-concentric water heater power vent / PVC vent pipe systems used by a high efficiency and high efficiency condensing storage / tank type water heaters. RXGY Concentric Vent Termination Kit Installation Instructions Revision 05 Keywords 92-25363-01-05, RXGY-E02, RXGY-E02A, RXGY-E03, RXGY-E03A, Concentric Vent Termination Kit, Installation Instructions Concentric Vent General The Concentric Vent allows both the intake for combustion air and the exhaust vent to pass through a standard roof or sidewall. It would be nice if vent flashing would last as long as the actual roof did. Follow furnace installation instructions for cleaning and cementing. The fan must exhaust outside the building, which requires the installation of a duct system. CONCENTRIC VENT TERMINAL INSTALLATION INSTRUCTIONS SUPPLEMENT TO INSTALLATION INSTRUCTIONS BSCII & PSCII & SCDFM WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Are you curious about roof vent installation? Learn more about how the systems work and how to install them with this quick guide. 5) Always have vent 1' above ground level, away from shrubs and bushes. D14. - 60 Inch Overall Ext. Combustion Horizontal Vent Kit to the tankless water heater. I am going to be buying a concentric vent/air kit so there is only one hole to drill  passedcode #newconstruction New construciton installation of the high efficiency furnace concentric vent. What can you Bathroom vent fan installation is easier if you have attic access. Seal the connection and all other vent pipe joints on the pressure side of the Power Venter with a high temperature silicone adhesive sealant or equivalent. 899. Install Y concentric fitting and pipe assembly through structure’s hole. For unit heaters, use on 60 through 125 MBH 4 Concentric Vent Kit for PTC Heater. Technical Documents. Be proactive and install our Concentric Vent Screen Kit with a Diamond Vent Screen in the exhaust pipe. The water heater shall use a commercial grade copper alloy, fin tube heat exchanger with quick release brass or bronze waterways. Determine correct Concentric Vent size for the pipe diameter selected. Please ref On installations of multiple BTH water heaters, install the concentric vent/air termination assemblies as described in this manual. Concentric Vent Kit. Concentric vents make it easier to have a two-pipe installation for high efficiency furnaces. H03R03612-002 – Tube Silicone Sealant (1) Part No. Check the manufacturer's installation  Includes (1) Combustion Air Inlet Cap, (1) Air Inlet Pipe, (1) Vent Pipe, (1) Intake/Vent Concentric Y, (1) Installation Instruction on Box. Concentric vents make it easier to have a twopipe installation for high efficiency furnaces. For CVENT-3. Installation Manual BK-CG-101 • 891152 WARNING Improper installation of Vent System and Components, or failure to follow installation instructions, can result in property damage or serious injury. Unfortunately many of us aren’t this lucky and the flashing will need to be replaced a Adding soffit vents introduces cool, fresh air to your attic as hot air escapes from the top of the attic through ridge vents, attic fans or gable vents. The reasons are outlined below. A typical installation looks like this: Other parts required are: (1) TK-TV09 - for Takagi Jr or (1) TK-TV10 - for The indoor heater shall be vented with a 3”/5” direct vent APNC35 concentric vent with a length not to exceed 43 ft. Updating Shipping Availability Standard Shipping. Clean and cement using procedures explained in the furnace HOW TO: HORIZONTAL CONCENTRIC VENT INSTALLATION: STEP-BY-STEPThis video shows typical steps during installation of horizontal concentric vent kit. Concentric Vent Kit Installation Guide Step 1 Cut a 6” diameter hole in the exterior wall of the building. The LMP shall submit a detailed sketch of the piping installation and wall penetration. The following flow reductions may be realized. 1 Concentric Vent Description Endurance concentric direct vent is a sealed-combustion system. For model: RTG 199HE TANKLESS WATER HEATERS. This item is accepts two inch pipe. Side note: a concentric vent looks like a one-pipe system, but it’s really one pipe inside of another. Additional Information Concentric Vent Kit (PDF) Concentric vents make it easier to have a two-pipe installation for high efficiency furnaces. diffusers shall consist of an aluminum supply diffuser with an aluminum eggcrate return. Install this furnace only in a location and position as specified in “Location and Clearances” (page 4), of these instructions. Proper research prior to installation is the key to simplifying the process. PolyPro single-wall vent system is listed for exhaust temperatures up to 230°F (110°C) with 0" clearance for vertical vent installations, and 1/4" (6mm) clearance for horizontal vent installations. UNIVERSAL CONCENTRIC VENT KIT (UCVK. Questions regarding the proper vent material are to be directed to your PB Heat, LLC representative. It’s basically the venting system o PRODUCT DETAILS This kit can be used for 3in. A bathroom needs ventilation as much as it needs lights, so a bathroom vent fan Installing roof ridge vents has several advantages, including adding value to your home. center of the hole in the wallplate. 2 m) Rising moisture will collect under eaves. For concentric 60/100 end 80/125, the minimum length of A must be . Concentric Vent Kit - 2 in. Ensure small diameter pipe is cemented and bottomed in Y concentric fitting. Combustion air for the Ultra boiler must The common vent system may not be used with the concentric or low profile vent terminals as described in the instruction manual supplied with the water heater. Without it, you could be wasting a lot of Safety is paramount when dealing with fire, so get that vent flue installed properly the first time. My feeling is if I am willing to invest to install an ERV, it might as well be done optimally. 1) Applies to: Models UDAS and UDBS, Sizes 30, 45, 60, and 75 Application Components This option is designed for horizontal venting of Models UDAS and UDBS Sizes 30, 45, 60, (1. , 3"/5" furnish and install, at locations shown on plans or in accordance with schedules, flush mount concentric diffusers manufactured in an iSo9001 facility. $38. See Fig. Sidewall installation . (See Figure 2 below). Concentric Vent Kits. ), can mount conveniently on a wall, vent easily, are “direct vented”, meaning they use outside air for combustion, and use 3″ PVC for both intake and exhaust. The special vent fittings and accessory concentric vent termination kits and accessory external drain trap have been certified to ULC S636 for 2. The pipe shall be installed so that the first 3’ of pipe from the appliance flue outlet is readily accessible Once Centrocerin (installation lubricant) has dried the gaskets provide firm junctions between components. These “pipe-in-pipe” kits allow for both exhaust and intake pipes to penetrate the roof or side wall through only one hole. Maximum flow rates up to 10. 24" (2ft) is the effect. Product Features: The use of a concentric vent kit allows for both the intake for combustion air and the exhaust vent to pass through one termination in a standard roof or sidewall. Sensor Installation Guideline 47 K-Factor 48 Electrical Connection 49 Remote Controller Installation 50 PCB Board Setting 51 Cascade Connection and Set-up Procedure 52 DIP Switch Setting 57 direct vent gas appliance must use its own separate vent system. Browse for more products in the same category as this item: Installation Supplies. The kit utilizes single wall penetration through exterior walls for both the fresh air intake and exhaust. They have combustion air supplied from the exterior (some water heater PVC vent pipe systems might be 2 pipes starting at the water heater and converted into one concentric The Concentric Vent allows both the intake for combustion air and the exhaust vent to pass through a standard roof or sidewall. (2. J30-03389 – Installation Instructions VENTING REQUIREMENTS Standard two pipe venting and concentric vent kits are certified by CSA International Reduce installation and maintenance costs for your Modine Hot Dawg HDS Heater with this Horizontal Concentric Vent Kit for HDS60-HDS125 heaters. . Only qualified personnel should install and service the equipment. CVENT-3 is for use with 3 in. General rules for vent terminations: Avoid locating the water heater vent terminator near any air intake devices . Vent systems must be composed of pipe, fittings, cements, and primers listed to ULC S636. WARNING. 095247107414. Allows combustion air to enter and exhaust to exit through single common hole. 9) must have a minimum length of 3” (40 mm). KGAVT0501 (2 in. This kit contains: Two Pipe to Concentric Appliance Adapter, 94 ۫degree elbow, Horizontal Termination, Trim A Concentric Diffuser provides conditioned air from a HVAC rooftop unit to a space, while returning air back to the rooftop unit through the same diffuser. 257R03605 – Flue Terminal Assembly (1) Part No. 855. Read this supplement and the unit heater installation, installation of the intake/vent pipe(s) and all furnace installa-tion procedures. J37R03604 – Inlet Air Screen (1) Part No. This is an alternative to the  Instead of a separate hole for the exhaust pipe and a separate hole for the combustion air intake pipe, this kit merges the two pipes into a single concentric  Ability to be installed vertically or horizontally · Made from tough durable, weather resistant PVC · Fits high efficiency Richmond condensing indoor gas tankless  Description Concentric Vent Kit 2" Used On GUH95T, GUH95A, GUH92A, GDD95A, GDD92A models NOTE Always verify before ordering. 4 or more concentric vent kits: Option 1 - keep all of installation. Video Playback Not Supported Adding soffit vents introduces cool, fresh air to your at Venting a clothes dryer to the outside isn't an option - it's a requirement. ) on all gas-fired condensing furnaces. Thanks guys, i appreciate the help. Cat #: 71M80. Concentric venting: The old Rudd PVP (Power Vented) water heaters used a 2" X 3" Increaser that fit over the outlet of the blower. Cement air inlet vent pipe and exhaust vent pipe to concentric vent termination assembly. Cement the Y concentric fitting to larger diameter kit pipe (see Fig. Seems that the installed may have reversed the pipes. • Concentric Vent Box • Air Outlet Cap • Combustion Air Inlet Cap Figure 1 • Kit Contents This instruction sheet is intended to describe the installation of the Concentric Vent Kit. Install vent pipe and combustion air pipe between unit heater and concentric vent adapter box as outlined in "Section A – General Instructions – All Units". Ship to - ( change) 3) Never install a heat saver or similar product to capture waste heat from exhaust. 3 4 is to assemble and install the flexible vent system. For additional and more detailed installtion procedues and maximum vent length dip switches adjustment (pg. Concentric Vent Install Incorrect? Hello, I just noticed that my concentric vent connected to a high efficiency furnace was exhausting through the combustion intake port area (downward facing) instead of the sky bound vertical stack. Refer to the appliance manufacturer’s installation Installation & Service Manual for Vertical Combustion Air Inlet Kits (Used with Separated Combustion Tubular Unit Heaters) concentric vent, X7-V5, X7-V6, J30-09023 36189 Sterling HVAC Products Installation & Operation Manual Gas Fired Unit Heaters, Indoor Products SC, SF, XC, XF VCAK-IOM-7. List Price: $42. The following PVC concentric vent kit is designed to provide one penetration point through the exterior wall or roof for both combustion air and exhaust vent piping. The most common use for these vent kit is for Model UDAS for residential garage installations. The roof or wall penetration of the terminal assemblies should be such that the vent outlet is a minimum 2” (30 cm) between the centerlines of adjacent vent terminals for installations in the U. 4) Always have vent location at least 1' above maximum snow level. • Photographs are representative only. A two-pipe system is preferable because the furnace won’t have to use heated indoor air for combustion. ) and KGAVT0601CVT (3 in. The concentric vent kit cannot be modified to attach a tee or elbow to the vent portion of the rain cap. The PVC concentric vent kit is compatible with the following Bosch Concentric Vent Kit for use when venting and combustion air is desired through a single wall or roof penetration. 3. The concentric vent kits are This integrated system allows both flue gases and fresh air to flow through a single component, reducing installation time and roof or wall penetrations. Refer to the information in this supplement to determine acceptable vent and air piping length. Once Centrocerin (installation lubricant) has dried the gaskets provide firm junctions between components. Product Description. Cement “Y” fitting to larger diameter air inlet pipe 2. • Combustion Air Inlet Cap. Does NOT include additional lengths of straight pipe. 6' (1. termination kit. (equivalent), terminating horizontally or vertically with no more than four 87° elbows. 6 Connecting to an Existing Vent System PVC Concentric Vent Manual Recess Box Water Heater Configurations & Installation Greentherm Replacing Control Unit: Models C150ES, C950ES Type Installation Manual Concentric Vent Kit Installation Guide 8-1/8” 7-1/2” 20-34” 25-3/16” 4-1/2” 4-15/16” 5-15/16” 12-3/4” NotICe It should be noted that a mild flow reduction may be realized with the use of a concentric vent. The application flexibility of the HDS separated combustion unit heaters are greatly enhanced when coupled with our concentric-vent kits. For single wall, the length of A (Fig. 8” (20 mm). Vent The Rheem SP20245, horizontal or vertical concentric vent termination kit, is a direct vent kit for high efficiency condensing tankless water heaters. Install a properly sized vent pipe section into inner pipe of the vent hood. InnoFlue® Flex is commonly combined with InnoFlue® Single Wall but can also be combined with InnoFlue® Concentric. , starting within 6' (1. In that installation separate intake and exhaust vent pipes are run between the water heater and interior wall, and only the wall penetration and • Concentric Vent Box • Air Outlet Cap • Combustion Air Inlet Cap Figure 1 • Kit Contents This instruction sheet is intended to describe the installation of the Concentric Vent Kit. First, with only one pipe There are also single-concentric water heater power vent / PVC vent pipe systems used by a high efficiency and high efficiency condensing storage / tank type water heaters. 25 Nov 2010 hey guys, I am almost done installing my TT Solo 60. Product UPC. Created Date: 6/4/2009 1:11:36 PM Concentric Vent Wye Exhaust Pipe Intake Pipe Rain Cap Stainless Bolt and Locknut Concentric Vent Kit Installation Considerations 1. 15-year heat exchanger warranty and 5-year parts warranty in residential applications. A two-pipe system is preferable because the furnace won't 8. Failure to understand and follow the manufacturer's installation and use instructions may result in fire or explosion,  The Ubbink Rolux® condensing concentric vent system was tested and approved with the Rinnai® to fix or install any damaged vent components. Combines a two pipe vent system to a single, concentric through-the-wall or roof penetration. 5 Concentric Vent for Combustion Air and Exhausting Flue Products 8. 8 m) Caulk zone or to edge of window etc. a. Refer to the furnace installation instructions for intake/ vent pipe sizing information. Vent kit positioned where the vent vapors will not damage planting/ shrubs or air conditioning equipment or building struc-ture. Concentric termination installation The Ultra boiler concentric vent system can only be terminated vertically (not intended for sidewall termination). The concentric vent piping for this boiler is approved for zero clearance to combustible construction. Concentric vents make it easier to have a two pipe installation for high efficiency furnaces. S. The supplied vent connector and vent termination are certified as part of the boiler. Determine the best location for the vent kit. 12" (1ft) is the effect. 6 Connecting to an Existing Vent System CONCENTRIC VENT ANY WARRANTY CONSIDERATIONS ARE CONTINGENT ON INSTALLATION BY A QUALIFIED INSTALLER (CONTRACTOR). Vent Concentric Vent Kit. Without it, you could be wasting a lot of money. Optional vent kit for Modine PTC heaters only and enables one penetration through exterior wall for both fresh air intake and exhaust. Cement the rain cap to the smaller diameter kit pipe (see Fig. unit shall be complete with a permanent non-adhesive anti-sweat gasket and If soft vent is too close, block off and install new vent at another location. Modine Concentric Vent Kit Installation Instructions 75-536. CNKT-0560-18HD Installation Instructions from MicroMetl Corporation on Concentric Vent Kit Installation Guide Step 1 Cut a 6” diameter hole in the exterior wall of the building. This kit is designed for use with the FA and UH Series when both venting and combustion air is desired through a roof or wall penetration. Sensor Installation 47 Outdoor Temp. Vertical Vent Installation Diagram Horizontal Vent Installation  It incorporates flue vent and air intake into a single pipe, allowing for significant space saving and installation versatility. KIT CONTENTS. VERTICAL DIRECT VENTING components and specified primers and glues of the certified vent system must be from a single system manufacturer and must not be intermixed with another system manufacturer’s parts. Failure to properly install the vent piping could result in flue gas leakage, causing possible severe personal injury, death or substantial property damage. Our Price: $ 28. - Examine all components for possible shipping damage prior to installation; - Proper joint construction is essential for a safe installation. 7. DO NOT APPLY TO A NON-CONDENSING  The Rheem SP20245, horizontal or vertical concentric vent termination kit, is a direct vent kit for high efficiency condensing tankless water heaters. By Michael Franco Photo: familyhandy Installing attics vents is simple with instruction. com Fireplace air vent installation can sometimes be difficult to figure out which air intake vent kit is right for you. This item is used for a two pipe high efficiency gas furnace. 0182 Telp: 832. SAFETY CONSIDERATIONS. Quick Installation Guide Model NPE-180A / 210A / 240A NPE-150S / 180S / 210S / 240S 1 Lift up the water heater, rest the unit Concentric Vent Termination A concentric vent termination may be used on a power direct vent tank or tankless water heater to get the same benefit of a single wall or roof penetration with an aesthetic vent termination. If ULC S636 compliance is required, use only System 636 pipe, fittings and cement. For use in U. 9 for proper installation. installation. 13 Installation Manual), refer to the the VK3-H-PVC (PVC Concentric Vent) Installation Manual. 8 m) Caulk zone or to Side note: a concentric vent looks like a one-pipe system, but it's really one pipe inside of another. According to Trey Hoffman, global product manager for Rinnai, concentric vents provide a couple of advantages. here is a pic of a properly installed vent here is an bad install pic Concentric vent design. Advertisement By: Vivien Bullen ­Your house is uncomfortably hot in the summer. Takagi on-demand water heaters have many excellent features. The concentric vent adaptor allows for the combustion air and vent piping with only one horizontal or vertical building penetration. SELF-INSTALLATION IS PROHIBITED AND WILL INVALIDATE YOUR WARRANTY. Use vent and termination kit combinations as stated in the furnace Installation and Start-Up Literature. The concentric vent kits are Note 1: Weil-McLain concentric vent kits are made from PVC pipe and fittings. In Canada, the primer and cement must be of the same manufacturer as the vent system -- IPEX System 636, Planning to install an ERV (Energy Recovery Unit) and have been advised that a concentric vent is easier to install and the risk of short circuiting output and input is negligible. Adequate ventilation is an extremely important addition to the roof, because without the proper ventilation the roof material will deteriorate faster t Does an over-the-range microwave need to be vented? Yes, if you want clean air after cooking! Here's how to install a microwave vent duct. Honestly, any of your options should be fine for a high-efficiency gas appliance and a three foot pipe run. • Check local codes and ordinances for permitted uses. NOTE: These instructions cover the installation of the concentric vent termination kits, NAHA00301CV & NAHA00401CV that are. Video Playback Not Supported Many times an over-the-range microwave that recirculates cooking fumes c A gable vent is an important part of the heating and cooling of your home. NOTE: Consider the following when determining the vent kit lo-cation: A. CONCENTRIC VENT TERMINATION KIT 3 6. 25-27 5. Minimum clearance from the concentric vent adaptor box to combustibles is 2” (50mm). Installing the flue is one of the most important jobs when you plan to install a direct vent fireplace. Innoflue Concentric is the only concentric polypropylene flue vent system on the market which is UL 1738 listed and approved by over 50 boiler, water heater and furnace manufacturers. installations, a UL 1738 vent system may be used only where the appliance manufacturer’s The sealed combustion chamber draws air for combustion from outside and exhausts through a concentric vent-pipe system to the outside – retaining heat and maintaining interior air quality. Step 3 • Concentric Vent Box. 6m) and three elbows. Eliminates unsightly elbows for a cleaner installation. DO NOT mix piping from different pipe manufactur - A concentric venting system may be the best option for use with many types of water heaters, including direct and power direct vent as well as tankless. The Concentric Vent allows both the intake for combustion air and the exhaust vent to pass through a standard roof or sidewall. Innoflue Concentric is made . 4m), the concentric vent kit cannot be used. It incorporates flue vent and air intake into a single pipe, allowing for significant space saving and installation versatility. It was a specific fitting that had a slot cut out of it. See Figure 4 for proper pipe attachment. 2 • Exclusive! Maintenance Notice Setting – Alerts homeowner – flashing a warning code to call for service check (optional) • Self-diagnostic system • 3"/5" concentric vent system with Integrated condensate collector • Connects to Metal Fab. 1 Concentric Direct Vent 2. conditions and will void the certification and the product warranty. The location of the vent termination shall comply with ANSI Z21. The ICVL352 from Centrotherm is a 3”/5” x 24” Innoflue Concentric Vent Pipe. VENT CONCENTRIC VENT ROOF INSTALLATION 4 INSTALLATION -SIDE WALL VENT (SEE FIGURE 5) 1. 5. InnoFlue® Single Wall, Flex, Concentric Vent System. packaged with the furnace, follow these  Simplify your venting installation with a Revolv concentric vent kit. The exhaust temperature of condensing, high-efficiency gas appliances is pretty low, which is why PVC is an option. These vents simplify installation and only require one hole through the wall or roof where the pipes terminate. The Ubbink Rolux condensing concentric vent design is part of the direct vent system, and has been tested and approved by CSA, a third party testing agency. PolyPro Concentric vent system parts, including the concentric Horizontal Termination and the Vertical Termination, are listed at 0” clearance But to stay with manufacture recommended installation for all goodman concentric vented units, it is recommended to have the vent 2ft taller than the nearest point within a 10 ft radius. (For models manufactured prior to 2008 a separate condensate collector is available) Plastic vent components consist of an outer plastic vent for the air intake Saf-T Vent® SC is a concentric vent system designed for zero clearance installation in light commercial and residential applications: Concentric venting speeds installation with exhaust and intake through one vent; Size 3"/5" and 4"/7" diameters (ID/OD) Reduced clearance to combustibles Concentric Vent Termination 42 Outdoor Installation 43 Pressure Reducing Valve 45 Outdoor Temp. A two-pipe system is preferable because the furnace won't furnish and install, at locations shown on plans or in accordance with schedules, flush mount concentric diffusers manufactured in an iSo9001 facility. Determine the best location for the intake/vent. 2" vent kit - coupling, sound suppressor 330828-000 3" vent kit - coupling, sound suppressor 330851-000 2" concentric vent kit 9008586005 3" concentric vent kit 9006328005 High ambient kit 9009024015 DIMENSIONS & SHIPPING WEIGHT Model Installation Height Height to Top of Tank Tank Diameter Overall Depth Height to Drain Valve Height to Gas Inlet This instruction covers installation of the concentric vent termination kits Part No. Add to Wish List. components and specified primers and glues of the certified vent system must be from a single system manufacturer and must not be intermixed with another system manufacturer’s parts. No additional fittings for outside connections are needed. Partially assemble Concentric Vent kit. b. Side Wall Vent Installations (Coaxial) is found in the Side Wall Vent Installation Section starting on page 14. Kits must be securely fastened to structure, to ensure clearance dimensions are maintained. 10/17/2019. You save $14. Concentric Vent Kit Side Wall Only 2" or 3" - 0170K00000S. If these instructions differ from those packaged with the furnace, follow these instructions. Vent termination shall not be located at lot line walls or within three feet of lot lines; installation must conform with the specifi cations listed in the tankless water heater installation manual. Cut a 4" diameter hole for 1CT0302, 2" kit, or a 5" hole for 1CT0303, 3" kit. Depending on the type of system (single wall or concentric) the support elbow can be shortened. Up to 100 CFM - 3% Up to 160 CFM – 7% Up to 200 CFM – 11 % Concentric Installation instruction COXCENTRIC PPs/Alu with COUPLING ULC-S636 bk-cg-100 • 891151 Warning Improper installation of Vent System and Components, or failure to follow installation instructions, can result in property damage or serious injury. 1CT0302 is for use with 2" intake/vent systems. Kit includes concentric vent adapter box and vent and combustion air terminals. The PVC concentric vent kit is compatible with the following Bosch Installation and service must be performed by a qualified installer, DIRECT VENT TANKLESS WATER HEATERS Acceptable Venting Clearances For IPEX Concentric Vent Concentric Vent Kit for use when venting and combustion air is desired through a single wall or roof penetration. ): Concentric Vent Termination - For use through rooftop, side-wall. Navien tankless water heaters & boilers for residential and commercial applications use innovative high efficiency technology to provide a comfortable environment. CONCENTRIC VENT KITS System 636 PVC & CPVC Concentric Vent Kits (CVK), are available in a variety of lengths and come in 2”, 3” and 4” diameters. 5600 Fax: 832. The maximum vent/air piping length depends on boiler size. 3"/5" x 24" Innoflue Concentric Vent Pipe. Condensate. Concentric vent terminational kit for water heater. For horizontal or vertical venting, requires only one hole to be cut rather than two and easy assembly. I will have a vent and intake up top and 180 degree fittings on them and also screened. Three Concentric Vent products are available: CVENT-2 is for use Concentric Vent Under My Deck When this spring I decided to reface and extend my deck I got a problem: How would I do it if the furnace concentric vent will be right under it? First of all it's against the code because the vapors which furnace produces will condensate on the joists. For a horizontal, sealed combustion installation, where the unit is vented through the same wall it is installed on (typically, right above it), and the wall thickness is within 5-10", a 2SVSHTC43S concentric vent kit is needed. in the proper installation of this concentric vent. 1). The best way to vent an attic is by having a proper roof vent system in place. Install rain cap and small diameter pipe assembly in roof penetration assembly. Add to Compare. Common vent systems are prohibited. S1-1CT0302 (2") & S1-1CT0302-636 (2") S1-1CT0303 (3") & S1-1CT0303-636 (3") Sidewall Vent Termination Kit - For use on sidewall, two-pipe The ICVL351 from Centrotherm is a 3”/5” x 12” Innoflue Concentric Vent Pipe. EXHAUST VENT/INLET AIR LOCATION 1. For unit heaters, use on 60 through 125 MBH 4 Direct-vent water heaters can use two separate pipes for intake and exhaust, but some manufacturers offer concentric venting, a single pipe that contains an inner exhaust vent and an outer intake vent. Refer to the Owner’s Use and Care Manual provided with your Direct Vent Tankless Water Heater for additional installation considerations and directions. VERTICAL DIRECT VENTING Home > Installation Supplies >. Option CC14, the Compact, Aesthetic, Concentric Vent/Com-bustion Air, Horizontal Vent Kit is for use with Model UDAS and UDBS in sizes 30, 45, 60, and 75. 1. pipe systems. if it is a high efficient furnace with pvc fittings you may use pvc and vent with 2 pipes or a concentric vent kit that allows air from the outside to feed the furnace while venting the exhaust through a smaller pipe inside. Copper heat exchanger: 25x better heat transfer than stainless steel. Additional Information Concentric Vent Kit (PDF) The kit makes it possible to use the optimal two-pipe installation for these furnaces while only cutting one hole through the wall or roof. C. for a metal piped system you will use the correct sized dual wall pipe and a concentric vent kit to penetrate through the closest rout to air outside of the home. A tee or elbow attached to the rain cap could potentially direct the flue gas plume toward the intake air stream and contaminate the incoming combustion air for the furnace. InnoFlue® Concentric is a special gas vent system always listed at zero clearance to combustibles. Item #: 904952. (G) Vent termination. This item is accepts three inch pipe. Only piping from the vent kit to the furnace will need to be provided separately. 16” 1” Step 2 Install the round foam gasket (provided) around the 6” galvanized duct and slide it up against the backplate. May 2014. While the material of a concentric vent may differ depending on the type of water heater you have, this aesthetic installation option refers to any coaxial “pipe in pipe” design. InnoFlue® Concentric is UL-1738 and ULC-S636 listed. 2m) and 8 ft. Carrier® Vent Terminal Kit, Concentric, Series: KGAVT, For Use With: Model 59SC2B Condensing Gas Furnace, 10 in W x 39 in D x 7-1/2 in H, Domestic Carrier_KGAVT0701CVT_installation_instruction () Type 8. Supports code compliance for NEC and OSHA standards. In this method, inlet and exhaust vent pipes run between your water heater and inner wall, and only your wall penetration and termination form the Side Wall Vent Installations (Coaxial) is found in the Side Wall Vent Installation Section starting on page 14. Flame retardant UL94 V-0 clear panels for safe visual inspection. 5601 sales@ventiairproducts. concentric vent kit, or 5” in diameter for 3” concentric vent kit. Direct Vent Installations (Two-pipe System) is found in the Direct Vent Section starting on page 24. The top of the hole should be a minimum of 1” from the bottom of the floor above (if applicable). Refer to the furnace rating plate. • Air Outlet Cap. These kits utilize single-wall penetration for venting purposes, reducing installation and maintenance costs. com Side note: a concentric vent looks like a one-pipe system, but it's really one pipe inside of another. Smith, INSTALLATION INSTRUCTIONS FOR 6” (15 cm) CONCENTRIC VENT TERMINATION DIRECT VENT SIDEWALL VENT MANUAL [PDF] A. Dealers, Distributors and Manufactures: If you are looking to purchase Diamond Vent Screens in large quantities, please fill out the contact form. This is still a two-pipe system. Sensor Outdoor Temp. Installation Instructions. This is an alternative to the standard two pipe intake and vent system in most power direct vent installations. A one-pipe system can be sidewall-vented, but will never be a direct vent. Product Features. Concentric Vent Termination . 782. 2. Concentric vent terminations are usable on power direct vent tanks or tankless water heaters to enjoy the same benefits as single wall and roof penetration with an appealing vent termination. (64 or 76 mm) diameter pipe systems. Length. Vertical Vent Installations (Coaxial) is found in the Vertical Vent Installation Section starting on page 18. 00. Fasten vent pipe connection with three sheet metal screws or with other appropriate type mounting screws. All of the air is drawn in from the outside Vertical Vent and Air with Vertical Concentric Termination Kit 17 22 16 21 3 2 1 5 20. I like concentric pipes because they only require a single penetration rather than two. DO NOT ATTEMPT TO CUT THIS VENTING MATERIAL. Use this kit and these instructions for installation of the concentric vent termination kit on  The Concentric Vent allows both the intake for combustion air and the exhaust vent to pass through a standard roof or sidewall.